Electric Vehicle Charging Framework in Singapore

Introduction

Electric cars first appeared in 1820, however, the limitations of power didn’t bring them to the limelight until the 20th century. Governments of several countries have shown great interest in adopting electric vehicles. As early as mid-2017, BlueSG Pte Ltd, a Bolloré Group subsidiary, will offer electric car-sharing services in Singapore. Additionally, electric vehicles reduce noise pollution, have low maintenance costs for consumers, make good use of vehicle space, and are easy to drive.

Despite the above developments, several factors still obscure the prospects of EV. A few of these factors are the battery life, charging time, availability of charging stations, the cost for charging, and safety. EVs might be required to be charged in scenarios where they still have reasonable charge and these scenarios could put the EV driver in a dilemma as the margin is limited compared to vehicles powered by internal combustion engines (ICEs)

Singapore is unique because it covers a total area of 719.1 km2 and averages about 50 km per day in car travel. EV charging stations in most countries are concentrated around specific neighborhoods and hence the cost of charging (uniform charging or dynamic charging) could significantly affect the EV user behavior. Electricity companies may charge different rates during non-peak times as well as during peak hours. Singapore does not have dedicated charging points since most people live in public flats.

EV Battery and Charger

Table 1 compares the battery power capacity, range, cost per km, and charging time for typical EVs currently available in the market for typical EV vehicles. Lithium-ion batteries require the least maintenance, are less susceptible to memory effect, and require no scheduled cycling. For subcompact EVs, the batteries have an energy capacity of 12 – 18 kWh, for mid-sized family sedans, 22 – 50 kWh, and for luxury models, such as those from Tesla, 60 – 85 kWh. The charging rate of the battery depends on the type of charger used and the initial charge in the battery.

Most EVs or EV users have smartphones that can be enabled to communicate with charging networks. The EVs could also be equipped with built-in communication modules. The charging network would be responsible for sharing the parameters in Table 3 while maintaining privacy. This information may also be used by EV manufacturers to examine their batteries and performance. Charging stations can analyze the charging patterns of EV users in order to adjust their pricing and business models.

Charging Station Selection Criteria

Our method of calculating travel times based on the Google Maps API allows us to rank the five easiest charging stations according to their travel times. Pricing factors affect the charging station criteria. Table 3 lists the parameters that we used when simulating an EV charging network with JAVA programming. We used the standard Singaporean exchange rate, which is S$3.99 to S$5.99. Google Maps was also used to calculate distance and estimate the charging station’s location.

Simulation

With the parameters listed in Table 3, we used JAVA programming to simulate the EVs and the 30 charging stations. Google Maps was used to estimate the distance between the EV and the charging stations as well as the time it would take to reach the charging station under realistic traffic conditions. We randomly assigned p! Singapore taxi rates with a flag down fee of S$3.40 and a per-kilometer fee of S$0.44 range from 5.99 to 14.99 Singapore dollars. Figure 1 illustrates EV charging stations in Singapore.

If you’re looking for the best place to get your power supplies, you’re in the right place! EP-Power together with Magna-Power aims to give you a total commitment to ensure the best quality and provide first-class products and services.

For inquiries, you may send us an email at: sales@edac.com.sg or give us a call at +6564547877.

 

What is Deep Discharge? How To Build A Simple Battery Protection Circuit

Batteries you use in a variety of projects, from uninterruptible power supplies to remote-controlled cars, may be damaged by deep discharging. Learn about deep discharging and how to protect your batteries. Here you will find helpful terms and a simple circuit that can protect your battery-powered projects from malfunctioning.

What is Deep Discharging?

A deep discharge occurs when the capacity of a battery has been exhausted. Battery cells have a set voltage at which they cease to function. This voltage is called the cut-off point. Exhausting deep causes 1.5 to 2 times as much electric discharge as the battery can support. As a result of over-discharging, the battery will have increased internal resistance, making charging difficult. The price tag on these batteries is high.

Depth of Discharge

According to the Depth of Discharge chart, the battery has used a percentage of its capacity as compared to its total capacity. If the batteries’ full capacity is 15kWh and you discharge 12kWh, that’s 96%. As a result, a deep discharge is something you should avoid. A deep cycle battery is a battery that is designed for deep discharge regularly. Power storage, UPS, traffic signals, and remote applications use these batteries.

Deep Discharge Protection Circuits

Identification of the battery’s cut-off voltage is necessary for deep discharge protection. A Zener diode in reverse bias condition will act as an open circuit when its cathode voltage falls below the breakdown voltage. It starts conduction when the cathode voltage is above its breakdown voltage. A switch disconnects the load from the battery, thus disconnecting the battery from the device. When the batteries reach the cut-off voltage level, we need to design a circuit to turn on a switch.

Protection Circuit for 12V Batteries

We will build a protection circuit to protect the load and battery from over-discharging, we will build a protection circuit. To adjust the resistance to achieve the desired range of operation, we’ll use a similar circuit but change the resistance. The diode is no longer conduction and there will be no base voltage, which effectively disconnects the battery from the load when the voltage is below 8V. We hope to use this circuit to protect the battery and the load from overcharging.

}