Description
Description
Fluke 107 ESP Palm-sized, CAT III Digital Multimeter

- Professional measurements in the palm of your hand
- AC/DC Voltage to 600V
- AC/DC Current to 10A
- Resistance & Continuity to check for broken wires
- Data hold & backlit display to keep you working safe and fast
The Fluke 107 is a compact, easy-to-use multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where true-rms accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time.
Complete Test Functions
- Including AC and DC voltage measurement
- AC and DC current measurement
- Resistance measurement
- Capacitance measurement
- Diode measurement
- Frequency and duty cycle test and other functions to meet basic electrical maintenance, electrical measurement, and electronic measurement applications
-
Manufacturer Specs
Electrical specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]) Function Range Resolution Accuracy AC volts (40 Hz to 500 Hz)1 6.000 V
60.00 V
600.0 V0.001 V
0.01 V
0.1 V1.0 % + 3 DC volts 6.000 V
60.00 V
600.0 V0.001 V
0.01 V
0.1 V0.5 % + 3 AC millivolts 600.0 mV 0.1 mV 3.0 % + 3 Diode test2 2.000 V 0.001 V 10 % Resistance (ohms) 400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3Capacitance3 50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.0 μF
1000 μF0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5Frequency4 (10 Hz to 100 kHz) 50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz0.1 % + 3 Duty cycle4 0.1 % to 99.9 % 0.1 % 1% typical5 AC current (40 Hz to 200 Hz) 4.000 A
10.00 A0.001 A
0.01 A1.5 % + 3 DC current 4.000 A
10.00 A0.001 A
0.01 A1.5 % + 3 Backlight – – Yes 1. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
2. Typically, open circuit test voltage is 2.0 V and short circuit current is < 0.6 mA.
3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).
4. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
5. Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.Function Overload protection Input impedance (nominal) Common mode rejection ratio Normal mode rejection ratio AC volts 600 V1 > 10 MΩ
< 100 pF2> 60 dB at dc, 50 Hz or 60 Hz – AC millivolts 600 mV >1M
<100 pF> 80 dB at 50 Hz or 60 Hz – DC volts 600 V2 > 10 MΩ
< 100 pF> 100 dB at dc, 50 Hz or 60 Hz > 45 dB at 50 Hz or 60 Hz 1. 6 x 105 V Hz Max
2. For mV (AC), input impedance is approximately 1 MΩ.General specifications Maximum voltage between any terminal and earth ground 600 V Display (LCD) 6000 counts, updates 3/sec Battery type 2 AAA, NEDA 24A, IEC LR03 Battery life 200 hours minimum Temperature Operating: 0 °C to 40 °C
Storage: -30 °C to 60 °CRelative humidity Operating Humidity: Non-condensing when < 10°C
≤ 90 % at 10 °C to 30 °C;
≤ 75 % at 30 °C to 40 °C
Operating Humidity, 40 MΩ Range:
≤ 80 % at 10 °C to 30 °C;
≤ 70 % at 30 °C to 40 °CAltitude Operating: 2000 m
Storage: 12,000 mTemperature coefficient 0.1 X (specified accuracy)/°C
(< 18 °C or > 28 °C)Fuse protection for current inputs 11 A, 1000 V Fast Fuse, Fluke specified part only Size (HxWxL) 142 mm x 69 mm x 28mm Weight 200 g IP rating IEC 60529: IP 40 Safety IEC 61010-1: 600 V CAT III, Pollution Degree 2 Electromagnetic environment IEC 61326-1: portable Electromagnetic compatibility Applies to use the Korea only.
Class A Equipment
(Industrial broadcasting and communication equipment)1Warranty One year 1. This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in home. Tech Specs
Multimeters Template
Style Hand-Held Measures DC V Yes True RMS Yes Maximum Voltage AC 600 V Resolution AC Volts 600 mV Maximum Voltage DC 600 V Maximum Current AC 10 A Maximum Current DC 10 A Counts 6000 . Backlight Yes Resistance Yes Frequency Yes Capacitance Yes Temperature Yes Diode Testing Yes CAT Rating III CAT Voltage 600 V Overload Protector Yes Data Hold Yes Test Equipment General Attributes
Unique Features Range: 0.1 % to 99.9 %
Resolution: 0.1 %
Accuracy: 1% typicalWarranty 1 YEARS IP Rating IP40 Product Weight 200 GRAMS (0.441 LBS) Product Height 142 MM (5.59 IN) Product Length 28 MM (1.10 IN) Product Width 69 MM (2.72 IN) HTS/Schedule B Number 9030.32.0000 ECCN Number 3A992 Battery Type AAA Power Supply Voltage Battery Powered Country of Origin China