Description

Fluke 114
- Ideal digital multimeter for “go/no-go” testing
- True RMS
- Measure to up to 600V AC/DC
- This model does not measure current
- Features AutoVolt automatic AC/DC voltage selection
Electrical Multimeter
Designed for easy one-handed operation, the compact Fluke 114 True RMS digital multimeter is the perfect troubleshooting tool for go/no go testing. Its AutoVolt capability automatically switches to measure AC or DC voltage, whichever is present. You can use the LoZ function to identify ghost voltage and prevent false readings.
The Fluke 114 displays True-RMS voltage readings with 6000 count resolution, and tests continuity and resistance. A large white LED backlight aids work in poorly lit areas and its easy-open battery access door makes battery changes quick.
A great choice for everyday troubleshooting, the Fluke 114 Electrical Multimeter is CAT III 600 V safety-rated and is a compact True-RMS meter.
Fluke 114 multimeters are independently tested for safe use in CAT III 600V environments.
Several versions available
Fluke offers several meters in its 110-meter series. The charts below outline several main differences in each.
In this chart,
- VoltAlert refers to non-contact voltage detection
- VCHEK is a LoZ low impedance measurement function to simultaneously test for voltage/continuity
- LoZ is a Low input impedance measurement to prevent false readings due to “ghost voltage”
To view additional selection information on the 110 series, please click here.
To view the selection information for the Fluke digital multimeter product line, please click here.
| 110 | 113 | 114 | 115 | 116 | 117 | |
| Counts | 6000 | 6000 | 6000 | 6000 | 6000 | 6000 |
| True RMS | AC | AC | AC | AC | AC | AC |
| Basic DC accuracy | 0.5% | 0.5% | 0.5% | 0.5% | 0.5% | 0.5% |
| AC bandwidth | 1kHz | 1kHz | 1kHz | 1kHz | 1kHz | 1kHz |
| Auto/manual ranging | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| AC/DC voltage | 600V | 600V | 600V | 600V | 600V | 600V |
| AC/DC current | 10A | 600µA | 10A | |||
| Resistance | 40MΩ | 60kΩ | 40MΩ | 40MΩ | 40MΩ | 40MΩ |
| Frequency | 100kHz | 100kHz | 100kHz | |||
| Capacitance | 9999µF | 9999µF | 9999µF | 9999µF | ||
| Temperature | 752°F | |||||
| Continuity/diode | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| VoltAlert | ✓ | |||||
| VCHEK | ✓ | |||||
| LoZ | ✓ | ✓ | ✓ | |||
| Microamps | ✓ |
In The Box
- Fluke TL75 Test leads
- Holster
- User’s Manual
- 9 V battery (installed)
Manuals/Guides
Manuals
Spec Sheets
Application Notes
- Digital Multimeters Application Notes
- Digital Multimeters 110 Series Application Note
- How Good Data Helps Manage PV and Microgrid Performance – Application Note
Other
Manufacturer Specs
| Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %.
The accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] ) |
| Maximum voltage between any terminal and earth ground | 600 V |
| Surge protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
| Display | Digital: 6,000 counts, updates 4/sec |
| Bar graph | 33 segments, updates 32/sec |
| Operating temperature | -10 °C to + 50 °C |
| Storage temperature | -40 °C to + 60 °C |
| Battery | 9 volt Alkaline, NEDA 1604A/IEC 6LR61 |
| Battery life | 400 hours typical, without backlight |
| Measurement | Range | Resolution | Accuracy ± ([% of reading] + [counts]) |
| DC millivolts | 600.0 mV | 0.1 mV | 2.0 % + 3 |
| DC volts | 6.000 V | 0.001 V | |
| 60.00 V | 0.01 V | ||
| 600.0 V | 0.1 V | ||
| Auto volts | 600.0 V | 0.1 V | 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
| AC millivolts1 true-rms | 600.0 mV | 0.1 mV | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| AC volts1 true-rms | 6.000 V | 0.001 V | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| 60.00 V | 0.01 V | ||
| 600.0 V | 0.1 V | ||
| Continuity | 600 W | 1 W | Beeper on < 20 W, off > 250 W; detects opens or shorts of 500 µs or longer. |
| Ohms | 600.0 W | 0.1 W | 0.9 % + 2 |
| 6.000 kW | 0.001 kW | 0.9 % + 1 | |
| 60.00 kW | 0.01 kW | ||
| 600.0 kW | 0.1 kW | ||
| 6.000 MW | 0.001 MW | ||
| 40.00 MW | 0.01 MW | 1.5 % + 2 |
| 1 | All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of = 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled. |
Tech Specs
Multimeters Template |
|
|---|---|
| Style | Hand-Held |
| Measures AC V | Yes |
| Measures DC V | Yes |
| Measures AC A | No |
| Measures DC A | No |
| True RMS | Yes |
| Maximum Voltage AC | 600 V |
| Resolution AC Volts | 0.1 mV |
| Maximum Voltage DC | 600 V |
| Resolution DC Volts | 0.1 mV |
| Basic Accuracy V DC | 0.5% |
| # Digit Display | 3.5 |
| Counts | 6000 . |
| Backlight | Yes |
| Manual/Autoranging | Both |
| Decibels | No |
| Resistance | Yes |
| Frequency | No |
| Capacitance | No |
| Temperature | No |
| Diode Testing | No |
| CAT Rating | III |
| CAT Voltage | 600 V |
| Intrinsically Safe | No |
| Peak Hold | No |
| Overload Protector | Yes |
| Kelvin 4-Wire Measurement Capability | No |
| Wireless Display | No |
| Data Hold | Yes |
| Low-Pass Filter | No |
Test Equipment General Attributes |
|
| Unique Features | Low input impedance ( LO-Z ) helps prevent false readings due to ghost voltage. Work in poorly lit areas with the Large white LED backlit display Record signal fluctuations using Min/Max/Average Integral holster with probe holders for easy storage Optional TPAK magnetic hanger allows the user hands-free flexibility |
| Warranty | 3 YEARS |
| Safety Approval | CSA, UL |
| IP Rating | IP42 |
| Product Weight | 1.21 LBS |
| Product Height | 1.82 IN |
| Product Length | 6.57 IN |
| Product Width | 3.31 IN |
| Data Logging | No |
| ECCN Number | 3A992 |
| Calibration Included | Factory Calibration |
| Battery Type | 9v |
| Power Supply Voltage | Battery Powered |